How do we replace the diesel generator turbocharger and what are the specific procedures?
1. Clean the engine and replace the filter element. Drain the dirty oil, add 70% diesel and 30% oil to the engine, start the engine and run for 3-5min to clean the engine and oil channel, then drain. Add an appropriate amount of oil, run for 5-10min and then drain. Replace the oil filter element and air filter element, filter and add clean lubricating oil until the oil scale is full to ensure that the engine oil and oil duct are clean and clean.
This article by Guilin New Ronghuang machinery Co., LTD